Initial commit: Check-My-IRVE SaaS (OCPP 1.6, Audit, Diagnostics)

This commit is contained in:
Adam Belkacemi 2026-08-25 19:08:15 +02:00
commit 192be86487
44 changed files with 2070 additions and 0 deletions

View file

@ -0,0 +1,99 @@
import math
def rule_missing_status_after_boot(frames, ctx):
if len(frames) < 3: return None
has_boot = any(f['action'] == "BootNotification" for f in frames)
has_status = any(f['action'] == "StatusNotification" for f in frames)
if has_boot and not has_status:
return {
"id": "NO_STATUS_AFTER_BOOT", "severity": "warning", "confidence": "medium",
"title": "Séquence de démarrage non conforme",
"explication": "Aucun StatusNotification n'a été reçu après le BootNotification.",
"action": "Envoyez un TriggerMessage(StatusNotification)."
}
return None
def rule_bad_websocket_ping(frames, ctx):
for f in reversed(frames):
if f['action'] == "GetConfiguration" and f['direction'] == "OUT":
config = f['payload'].get('configurationKey', [])
for item in config:
if item.get('key') == 'WebSocketPingInterval' and item.get('value') == '0':
return {
"id": "BAD_PING_INTERVAL", "severity": "critical", "confidence": "high",
"title": "WebSocketPingInterval désactivé (0)",
"explication": "La borne n'envoie pas de ping. Derrière une box FAI (NAT), la connexion sera coupée.",
"action": "Corrigez cette valeur à 60 depuis l'onglet Audit Config."
}
return None
def check_electrical(borne_config_dict, installer_config):
findings = []
max_c_str = borne_config_dict.get("MaxCurrent", {}).get("value")
disj_str = str(installer_config.get("disj_calibre", "0"))
p_decl_str = str(installer_config.get("borne_puissance", "0"))
raccordement = installer_config.get("raccordement", "")
if not (max_c_str and disj_str and p_decl_str): return findings
try:
max_c = int(max_c_str)
disj = int(disj_str)
p_decl = int(p_decl_str)
# a) Sécurité disjoncteur
if disj < max_c:
findings.append({
"id": "ELEC_UNDER_PROTECTED", "severity": "critical", "confidence": "high",
"title": "Protection sous-dimensionnée",
"explication": f"Disjoncteur {disj}A inférieur au courant max borne {max_c}A.",
"action": "Risque de déclenchement en charge. Vérifier le calibre et la section de câble."
})
# b) Puissance réelle vs déclarée
if "mono" in raccordement:
p_reelle = 230 * max_c
else:
p_reelle = 400 * max_c * math.sqrt(3)
p_reelle_kw = round(p_reelle / 1000, 1)
if p_reelle_kw < p_decl * 0.85:
findings.append({
"id": "ELEC_POWER_BRIDLED", "severity": "critical", "confidence": "high",
"title": "Borne bridée logiquement",
"explication": f"Borne bridée à {p_reelle_kw} kW ({max_c}A x {400 if 'tri' in raccordement else 230}V) alors que {p_decl} kW sont déclarés.",
"action": "Le firmware limite le courant. Vérifier le paramétrage usine ou une limitation logicielle."
})
# c) 22kW sur Mono
if p_decl > 7.4 and "mono" in raccordement:
findings.append({
"id": "ELEC_MONO_OVERPOWER", "severity": "critical", "confidence": "high",
"title": "Raccordement incohérent",
"explication": f"Puissance {p_decl}kW déclarée sur du monophasé.",
"action": "Au-delà de 7.4kW, le triphasé est obligatoire."
})
except ValueError:
pass
return findings
def analyze_frames(frames, cp_data, installer_config=None):
findings = []
# Rècles comportementales
rules = [rule_missing_status_after_boot, rule_bad_websocket_ping]
for rule in rules:
res = rule(frames, cp_data)
if res: findings.append(res)
# Règles électriques (nécessitent la config installateur)
if installer_config:
borne_config_dict = {}
for f in reversed(frames):
if f['action'] == "GetConfiguration" and f['direction'] == "OUT":
borne_config_dict = {k["key"]: k for k in f['payload'].get('configurationKey', [])}
break
findings.extend(check_electrical(borne_config_dict, installer_config))
return findings